Part Number Hot Search : 
502I33 STRX6700 AZ9891H PT2294 245MT MX25L1 EN25P80 2S140
Product Description
Full Text Search
 

To Download 587BXXX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 05016
587B051
thru
Only One Name Means ProT ek'TionTM
587B301
120V AC POWER LINE SURGE SUPPRESSOR
APPLICA TIONS Hard Wired Equipment AC Power Protection Load Side Distribution Systems Secondary Protection for Light Industrial AC Power IEC COMPA TIBILITY (EN61000-4) 61000-4-5 (Surge): 1kA, 8/20s - Level 4(Line-Line) & 333A Level 4(Line-Ground) FEA TURES
U.S PA TENT 4,563,720

Meets ANSI/IEEE C62.41 Requirements Listed to CSA, File LR65240 Differential and Common Mode Protection Low Clamping Voltage Nanosecond Response Time Long Life and Maintenance Free
Kilovolts
FIGURE 1 TRANSIENT VOLTAGE THREAT CONDITION
8 6
MECHANICAL CHARACTERISTICS Plastic Package Weight: 485 Grams (Approximate) Flammability Rating UL 94V-0 Device Marking: Part Number, Date Code, Logo, Voltage and Current Rating DESCRIPTION The 587B Series of 120 Volt AC Surge Suppressors is designed for use by the OEM, equipment installer and or maintenance contractor. These modules employ a three stage technology proven to be the most cost effective and reliable method in protecting sensitive electronic equipment from over voltage transients. This series is designed to protect AC powered equipment from the 6,000 Volt peak open circuit voltage and 3,000 Amp short circuit current as defined in ANSI/IEEE C62.41, Category C1. The 587B Series offers a high degree of protection against 120 VAC EMI line noise. It is ideal for protecting 400 Volt components because the solid state TVS technology assures that the line-to-neutral voltage will not exceed 400 Volts. While the modules are designed for transient voltage protection, the advanced circuitry will also attenuate the amplitude and slow the rate of rise of high frequency noise acting as an EMI filter. The 587B Series includes differential mode and common mode protection, which is effective in reducing interference from line to equipment and are effective in reducing equipment generated noise to meet FCC, VDE and CSA interference requirements.
4 2 0 0 10 20 30 40 50 60 Time - s
FIGURE 2 TYPICAL CLAMPING ACTION OF A 16 AMP MODULE
6 4
Kilovolts
2 0
0
10
20 30 Time - s
40
50
60
Figures 1 and 2 are photographs of digitized waveforms showing the typical clamping action of a 16 ampere module. A 12 Ohm resistor is used to represent a 10 Amp equipment load. The load is then subjected to the ANSI/IEEE C62.41 Category CI test conditions (6,000V/3,000A). These photographs contrast the effect on equipment with and without the protector.
05016.R4 12/03
1
www.protekdevices.com
587B051
thru
587B301
DEVICE CHARACTERISTICS
SPECIFICATIONS @ 25C
MAXIMUM RATINGS
Operating Line Voltage: 130 VAC Max Maximum Line Current: 587B051: 5A 587B151: 15A 587B201: 20A (Line-to-Neutral Only) 587B301: 30A Transient Voltage: 6000Vpeak Transient Current: 3000Apeak Current Leakage: Line-to-Neutral: Neutral-to-Ground: Storage & Operating Temperature: (Measured at center of mounting surface) @ 130 VAC 1.0mA 0.5mA -40C to 85C Frequency (MHz) Common Mode Attenuation Differential Mode Attenuation
0.15 10 30 0.5 25 55 1.0 35 55 5.0 55 55 10 50 50 30 40 45
RESPONSE TO TRANSIENT VOLTAGES
CLAMPING PROTECTION MODE DIFFERENTIAL (Line-to-Neutral) COMMON (Neutral-to-Ground) MAXIMUM CLAMPING VOLTAGE 295V 350V 500V 650V TEST CONDITION OPEN CIRCUIT VOLTAGE @ 1.2/50 s 1000V 6000V 1000V 6000V SHORT CIRCUIT CURRENT @ 8/20 s 500A 3000A 500A 3000A
FILTER CHARACTERISTICS (Noise Attenuation dB)
ARRESTER DEFINITIONS
Clamping Voltage: The clamping voltage of an arrester is the voltage that appears across its terminals during conduction of a transient current. Standard Wave Form: The waveform of a surge current or voltage is designated by a combination of two numbers. The first number is for the time of the wave front expressed in microseconds from zero to the peak of the wave. The second number is for the time of the wavetail also expressed in microseconds from zero to the instant that the wavetail reaches one half of the crest or peak value, i.e., 8/20 s waveform. Transient Current: The transient current of an arrestor is the peak surge current which flows through the arrester when voltage clamping occurs.
OPERA TION
For maximum effectiveness, the protector should be installed directly after the AC line on/off switch and fuse. This will protect the electronics from the AC line switch arcing and the severe transients caused by a fuse clearing. Some heat is produced when operating at full current load, and heat sinking may be required to maintain case temperature below 85C. The case temperature is measured at the center of the mounting surface. The unit should not be mounted to a low combusting temperature material such as wood. High energy transients will cause a large circulating current in the AC input line (2,500A is possible). To prevent electromagnetic coupling, the AC line on the input side of the protector must be dressed away from other wiring, magnetic shielding may be required. In addition, the electrical service must be connected to a low impedance earth ground.
05016.R4 12/03
2
www.protekdevices.com
587B051
thru
587B301
PACKAGE OUTLINE & DIMENSIONS
D C F E
LINE IN
LINE OUT
Model 587B051
120V 50/60 Hz 5 AMP
NEUTRAL
GROUND
0.169" Nom. Dia. 2 Places
A
PROTEK PART NUMBER A 2 3 3 3 B 2 2 3 3
CASE (INCHES)
37464-00001
B
INCLUDES HARDWARE 2 NUTS, 2 WASHERS PER TERMINAL
CASE (CENTIMETERS)
APPROX. WEIGHT IN GRAMS F 1.52 1.52 1.52 1.52
TERMINAL THREADS
587B051 587B151 587B201 587B302
C 2.5 3.5 3.5 3.5
D 2.85 3.85 3.85 3.85
E 1.5 1.5 1.5 1.5
F 0.6 0.6 0.6 0.6
A 5.08 7.62 7.62 7.62
B 5.08 5.08 7.62 7.62
C 6.35 8.89 8.89 8.89
D 7.62 10.16 10.16 10.16
E 3.81 3.81 3.81 3.81
250 500 750 850
#8-32 #8-32 M5 M5
COPYRIGHT (c) ProTek Devices 2003 SPECIFICATIONS: ProTek reserves the right to change the electrical and or mechanical characteristics described herein without notice (except JEDEC). DESIGN CHANGES: ProTek reserves the right to discontinue product lines without notice, and that the final judgement concerning selection and specifications is the buyer's and that in furnishing engineering and technical assistance, ProTek assumes no responsibility with respect to the selection or specifications of such products.
ProTek Devices 2929 South Fair Lane, Tempe, AZ 85282 Tel: 602-431-8101 Fax: 602-431-2288 E-Mail: sales@protekdevices.com Web Site: www.protekdevices.com
www.protekdevices.com
05016.R4 12/03
3


▲Up To Search▲   

 
Price & Availability of 587BXXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X